Rheem Ac Unit Fan Not Working

I have a rheem ac unit and a honeywell th8000 thermostat.
Rheem ac unit fan not working. Remove the service panel on the a c unit. The ac unit is not cooling. Easily troubleshoot electrical contactor. With the heat pump fan not working the compressor can overheat and be damaged and that will increase your repair bill by 1 250 to 2 000 plus.
If your unit is still under warranty with rheem contact rheem so as to not violate the terms of your warranty. Relay boards are often misdiagnosed. Do not attempt to work on your air conditioning unit unless all power to the unit is turned off. Find the start capacitor for the fan.
Rheem condensing unit not coming on. I ve powered everything on a read more. Find the cause of air conditioning system failure in ten minutes or less. Do not run a heat pump or air conditioner without the fan working.
Find the most common problems that can cause a rheem air conditioner not to work and the parts instructions to fix them. One purpose of the fan is to cool the compressor. This article discusses the diagnosis and repair of problems with the outdoor compressor condenser fan and fan motor including fans that wont run fans that run at slow speed and fans that won t stop running our page top photo of a compressor condenser fan unit shows that a stick had fallen into the fan blocking the blades and. Before replacing the board make sure you check more commonly defective parts particularly the fan motor capacitor and the fan motor itself.
A c or heat pump fan condenser unit diagnosis repair. Do not proceed if you re not sure you ve properly shut off the power. The fan on the unit is on and the furnace fan is blowing air but the air is not cool. If the relay board isn t working properly the fan might not run.
Air conditioner fan not working. The relay board provides voltage to many components of the air conditioner including the fan motor. Shut off the power supply to the air conditioner at the disconnect or breaker panel. Is your ac fan not working or spinning.
11 possible causes and potential solutions. Fan will not come on in the on position or your fan will not come on when you turn the thermostat down in the air conditioning mode. Test to make sure you are getting 24 to 28 volts ac between the g green and c com terminals on you fan center or control board if you aren t getting 24 volts between g and c then you might have a thermostat problem a thermostat. It s possible that it is simply not getting power or that the capacitor is dead but the condenser fan motor itself is.
It s located on the side of the building near the outdoor a c unit.