Riser Room Sign Requirements

Clearly marked sprinkler riser rooms could make a life or death difference in an emergency situation.
Riser room sign requirements. Ada sign mounting height requirements the baseline of the tactile copy can be mounted between 48 at the lowest point to 60 at the highest point. And to those who access the room. For instance if the riser room is placed at the far end of a large industrial building installers will most likely have to increase the pipe size to remote systems. Important factors to consider when choosing a location for the riser room include.
Your new fire riser room sign is manufactured from durable high quality materials making it the perfect choice for a number of locations and conditions. The letters designating the identification of the interior exit stairway and ramp shall be not less than 1 1 2 inches 38 mm in height. The national fire protection association nfpa 13 standard for the installation of sprinkler systems specifies many different requirements for the types of signage that sprinkler systems must include. The sign must be present at the system control riser antifreeze loop and auxiliary system control valve and must have up to 19 different pieces of information.
What is clear is that they are required for your system to be in compliance with the. Fire riser room sign made out of 040 rust free aluminum indoor outdoor use uv protected and fade resistant 7 x 10 by my sign center 4 0 out of 5 stars 1 10 48 10. The riser room s location can impact a sprinkler system s installation costs as well. If the room has a lock then the key needs to be always available to those who need to access the room.
Durable signs that last. As with certain other signs it must be a permanently marked weather proof metal or rigid plastic sign secured with corrosion resistant wire chain or other acceptable means 25 6 2. Fortunately easy to read sprinkler riser room signs identify this critical area for workers and emergency personnel. Fire pump and riser rooms shall be maintained to be no lower than 40.
Order your new signs direct from the usa manufacturer. The signs shall be a minimum size of 18 inches 457 mm by 12 inches 305 mm. Sprinkler riser room signs and labels. Ifc section 1023 9 1 signage requirements.
When a building is equipped with multiple fire protection systems a diagram indicating the location of all control. Signage is required on the access doors to fire pump and riser rooms and shall consist of letters at least two inches in height. This sign shall be protected from damage vandalism and shall be laminated or protected and permanently mounted on the wall in the facp riser room. This allows signs of different sizes to be mounted on the same visual plane.